| Output Volt Amp Capacity (VA) | 1000 |
| Output Watt Capacity (watts) | 500 |
| Nominal Output Voltage(s) Supported | 115v; 120v |
| Frequency compatibility | 60 Hz |
| Output voltage regulation (Battery mode) | 115V (+/- 5%) |
| Built-in UPS output receptacles | 8 5-15R outlet(s) |
| Surge suppression only outlets | 4 UPS outlets, 4 surge-only outlets |
| Output AC waveform (AC mode) | Sine wave |
| Output AC waveform (battery mode) | PWM sine wave |
| Rated input current (at maximum load) | 12A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS input connection type | 5-15P; Space saving right angled input plug |
| UPS Input cord length (ft.) | 6 |
| UPS Input cord length (m) | 1.8 |
| Recommended Electrical Service | 15A 120V |
| Full load runtime (minutes) | 3 min. (500w) |
| Half load runtime (minutes) | 9 min. (250w) |
| DC system voltage | 12V DC |
| Battery recharge rate (included batteries) | Less than 20 hours from 10% to 90% |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89 |
| Undervoltage correction | Input voltages between 89 and 104 are boosted by 14% |
| LED Indicators | Front panel LCD display |
| Front panel LCD display | Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing |
| Alarms | Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert software |
| Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| UPS AC suppression joule rating | 480 |
| UPS AC suppression response time | Instantaneous |
| UPS Dataline suppression | 1 line TEL / DSL protection (1 in / 1 out); Coax surge suppression jacks (1 set) |
| EMI / RFI AC noise suppression | Yes |
| Installation form factors supported with included accessories | Tower |
| Primary form factor | Tower |
| UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 12 x 3.7 x 7.2 |
| UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 30.5 x 9.4 x 18.3 |
| Secondary form factor | Horizontal desktop placement |
| Installed whole system dimensions in secondary form factor (height x width x depth / inches) | 3.7 x 12 x 7.2 |
| UPS dimensions in secondary form factor (height x width x depth / cm) | 9.4 x 30.5 x 18.3 |
| UPS / Power Module weight (lbs) | 15.5 |
| UPS / Power Module weight (kg) | 7 |
| UPS Shipping dimensions (height x width x depth / inches) | 10.4 x 15.6 x 4.8 |
| UPS Shipping dimensions (height x width x depth / cm) | 26.5 x 39.5 x 12.3 |
| Shipping weight (lbs) | 15.8 |
| Shipping weight (kg) | 7.2 |
| UPS housing material | ABS |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) | 52.6 |
| Battery mode BTU / hr. (full load) | 536.8 |
| Communications interface | USB (HID enabled) |
| PowerAlert software | Free download from www.tripplite.com |
| Communications cable | USB cable included |
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Transfer time | 4 milliseconds |
| Low voltage transfer to battery power (setpoint) | 89 |
| High voltage transfer to battery power (setpoint) | 139 |
| Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
| Green & high efficiency features | Greater than 95% efficiency - GREEN UPS |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); Meets FCC Part 68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous Substances) |
| Standard warranty period | 3 years |
| Connected equipment insurance (USA, Canada, Puerto Rico) | $200,000 connected equipment insurance |