| Output Volt Amp Capacity (VA) | 1500 |
| Output kVA capacity (kVA) | 1.5 |
| Output Watt Capacity (watts) | 900 |
| Nominal Output Voltage(s) Supported | 115v; 120v |
| Frequency compatibility | 60 Hz |
| Output voltage regulation (line mode) | -18%, +8% |
| Output voltage regulation (Battery mode) | 115V (+/- 5%) |
| Built-in UPS output receptacles | 8 5-15R outlet(s) |
| Basic PDU options | PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets); PDUV15 (0U / 12 5-15R outlets) |
| Metered PDU options | PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets) |
| Switched PDU options | PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets) |
| External PDU redundancy options | *Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS models only |
| Output AC waveform (AC mode) | Sine wave |
| Output AC waveform (battery mode) | PWM sine wave |
| Rated input current (at maximum load) | 8.5A |
| Nominal Input Voltage(s) Supported | 120V AC |
| UPS input connection type | 5-15P; Space saving right angled input plug |
| Input circuit breaker | 10A |
| UPS Input cord length (ft.) | 6 |
| UPS Input cord length (m) | 1.8 |
| Recommended Electrical Service | 15A 120V |
| Full load runtime (minutes) | 3.5 min. (900w) |
| Half load runtime (minutes) | 13 min. (450w) |
| DC system voltage | 24V DC |
| Battery recharge rate (included batteries) | Less than 4.5 hours from 10% to 90% |
| Voltage regulation description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
| Overvoltage correction | Input voltages between 128 and 147 are reduced by 12% |
| Undervoltage correction | Input voltages between 93 and 107 are boosted by 14% |
| Severe undervoltage correction | Input voltages between 75 and 92 are boosted by 30% |
| LED Indicators | Front panel LCD display |
| Front panel LCD display | Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing |
| Alarms | Audible alarm indicates power-failure and low-battery conditions |
| Alarm cancel operation | Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status |
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| UPS AC suppression joule rating | 480 |
| UPS AC suppression response time | Instantaneous |
| UPS Dataline suppression | 1 line TEL / DSL or 10Base T Ethernet protection |
| EMI / RFI AC noise suppression | Yes |
| Installation form factors supported with included accessories | 4 post 19 inch rackmount (mounting kit included); 2 post 19 inch rackmount (mounting kit included); Tower |
| Included mounting accessory description | Pair of mounting ears enable tower and 2-4 post rackmount installation |
| Primary form factor | Rackmount |
| UPS / Power Module dimensions in primary form factor (height x width x depth / inches) | 3.5 x 17.2 x 10.5 |
| UPS / Power Module dimensions in primary form factor (height x width x depth / cm) | 8.9 x 43.8 x 26.7 |
| Installed whole system maximum rack depth (inches) | 10.5 |
| Installed whole system maximum rack depth (cm) | 26.7 |
| Installed whole system total rack space height (rack spaces) | 2U |
| Secondary form factor | Tower |
| Installed whole system dimensions in secondary form factor (height x width x depth / inches) | 17.2 x 3.5 x 10.5 |
| UPS dimensions in secondary form factor (height x width x depth / cm) | 43.8 x 8.9 x 26.7 |
| UPS / Power Module weight (lbs) | 29.4 |
| UPS / Power Module weight (kg) | 13.3 |
| UPS Shipping dimensions (height x width x depth / inches) | 7.5 x 15 x 21.5 |
| UPS Shipping dimensions (height x width x depth / cm) | 19 x 38.1 x 54.6 |
| Shipping weight (lbs) | 33.4 |
| Shipping weight (kg) | 15.2 |
| UPS housing material | ABS |
| Cooling method | Fan |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC mode BTU / hr. (full load) | 266.1 |
| Battery mode BTU / hr. (full load) | 626.7 |
| Communications interface | USB (HID enabled); DB9 Serial |
| Network monitoring port description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert software | Free download from www.tripplite.com |
| Communications cable | USB and DB9 Serial cabling included |
| WatchDog compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Transfer time | 2-4 milliseconds |
| Low voltage transfer to battery power (setpoint) | 75 |
| High voltage transfer to battery power (setpoint) | 147 |
| Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); Meets FCC Part 68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous Substances) |
| Standard warranty period | 3 years |