Part #: SMART3000RMXLN

Item Code: PPTRP00103

Tripp Lite SMART3000RMXLN UPS System with Pre-installed SNMPWEBCARD - 2U Rack/Tower - AVR - 5 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 110 V AC, 115 V AC, 120 V AC Output - 1 x NEMA L5-30R, 8 x NEMA 5-15/20R

SmartPro 3kVA 2.88kW Line Interactive Extended Run UPS, Sine wave, Pre-installed SNMPWEBCARD, 2U, LCD, USB, Serial, EPO, 120V
search
  • SmartPro 3kVA 2.88kW Line Interactive Extended Run UPS, Sine wave, Pre-installed SNMPWEBCARD, 2U, LCD, USB, Serial, EPO, 120V

Part #: SMART3000RMXLN

Item Code: PPTRP00103

Tripp Lite SMART3000RMXLN UPS System with Pre-installed SNMPWEBCARD - 2U Rack/Tower - AVR - 5 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 110 V AC, 115 V AC, 120 V AC Output - 1 x NEMA L5-30R, 8 x NEMA 5-15/20R

$2,552.99
Qty:

Availability

CUSTOM ORDER
AVAILABLE TO ORDER
Custom order products are not eligible for returns unless defective.
Delivery time may vary for Custom Order products. You will be notified once your order is ready to ship.

Main Features

  • 3kVA / 3000VA / 2880W line interactive 2U rack/tower UPS; 0.96 power factor
  • 120V nominal output during brownouts to 83V and overvoltages to 145V
  • Interactive LCD provides UPS status information and advanced configuration options
  • Expandable runtime, Hot-swap batteries, 96% efficiency, Sine wave output
  • USB, RS232 & EPO ports, Pre-installed WEBCARDLX Network Interface Card
  • 2 independently switchable output load banks
  • NEMA L5-30P input; 8 NEMA 5-15/20R & 1 L5-30R outlets

Marketing Information

3kVA/3kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments

The SMART3000RMXLN provides reliable battery backup and AC power protection for connected devices against blackouts, brownouts, surges and line noise. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Pure sine wave power and unity power factor, even when on battery, means this SmartPro® UPS can be used with sensitive IT equipment, including servers, VoIP phones, data storage and PoE switches. Even if the battery is depleted, the UPS will automatically restart when the power comes back on after an extended outage.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately).

NEMA Outlets Protect Your Connected Components

One L5-30R and six managed 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.

Pre-Installed LX Platform Network Management Card Allows Remote Access 24/7

The WEBCARDLXE network interface enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring

The two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.

Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions

AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART3000RMXLN maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better

This UPS filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.




Customer Reviews

This item does not have any reviews yet

Be the first to write a review

Show All Reviews
Loading All Reviews